Elektro Kalori Ürün Kataloğu
21 1 Threaded globe valves Typical applications Actuators Data sheet – Radiators RTN.. N2111 RTN51/RTN51G RTN71 RTN81 PN 10 1...120 °C DIN NF DN Rp/R [Inch] k v [m 3 /h] ∆p max [kPa] ∆p max [kPa] ∆p max [kPa] Data sheet N2105 N2106 VDN110 VDN210 10 Rp/R 0.09…0.63 60 60 60 VDN115 VDN215 15 Rp/R ½ 0.10…0.89 60 60 60 VDN120 VDN220 20 Rp/R ¾ 0.31…1.41 60 60 60 VEN110 VEN210 10 Rp/R 0.09…0.63 60 60 60 VEN115 VEN215 15 Rp/R ½ 0.10…0.89 60 60 60 VEN120 VEN220 20 Rp/R ¾ 0.31…1.41 60 60 60 – VUN210 10 Rp/R 0.14...0.60 60 60 60 – VUN215 15 Rp/R ½ 0.13...0.77 60 60 60 PN 10 1...110 °C DN Rp/R [Inch] k v [l/h] ∆p max [kPa] ∆p max [kPa] Data sheet N2103 VD115CLC 15 Rp/R ½ 0.25...1.9 150 150 VD120CLC 20 Rp/R ¾ 0.25...2.6 150 150 VD125CLC 25 Rp/R 1 0.25...2.6 150 150 Typical applications Actuators Data sheet 4.5 mm 2.5 mm 4.5 mm – Radiators STA.. SSA.. N4884 N4893 100 N 100 N 90 N Operating voltage Positioning signal Positioning time [s] AC 230 V 2-position 210 STA23 – STA23HD 1) 3-position 150 – SSA31 – AC 24 V 3-position 150 – SSA81 – 0...10 V 270 2) STA63 – – AC/DC 24 V 2-position/PDM 270 STA73 – STA73HD 1) 0...10 V 34 – SSA61 – Normally Open / Normally Closed (for radiator valves) NC – NC Threaded globe valves Typical applications Actuators Data sheet 4.5 mm 2.5 mm – Chilled ceilings STA.. SSA.. N4884 N4893 100 N 100 N Operating voltage Positioning signal Positioning time [s] AC 230 V 2-position 210 STA23 – 3-position 150 – SSA31 AC 24 V 3-position 150 – SSA81 0...10 V 270 2) STA63 – AC/DC 24 V 2-position/PDM 270 STA73 – 0...10 V 34 – SSA61 Normally Open / Normally Closed (for radiator valves) NC – Presettings for radiator valves VEN.., VDN.., VUN.. k v values [m 3 /h] at the different preadjusted positions (XP = 2K) Control range with electromotoric and electrothermic actuators SSA.., STA.. – Control range with thermostatic head RTN.. Reference numbers for preadjustment 1 2 3 4 5 N N (k vs ) VDN110/VDN210/VEN110/VEN210 0.072 0.17 0.24 0.28 0.37 0.43 0.63 VDN115/VDN215/VEN115/VEN215 0.07 0.17 0.28 0.36 0.45 0.50 0.89 VDN120/VDN220/VEN120/VEN220 0.22 0.35 0.44 0.52 0.60 0.71 1.41 VUN210 0.14 0.26 0.34 0.39 0.40 0.43 0.60 VUN215 0.13 0.22 0.30 0.39 0.45 0.50 0.77 1) 2) In control mode (warm-up time) min. running time approx. 30 s/mm k v at the respective stroke and a differential pressure of 100 kPa (1 bar) The selected kv values of the radiator valves can be easily and precisely set on the valve head in 5 steps + N (fully open). Acvatix Valves and Actuators BİNA OTOMASYON ÜRÜNLERİ /SEÇİM TABLOLARI
powered by ikedijital.com
RkJQdWJsaXNoZXIy MTczMDA=