2 13 Threaded globe valves Typical applications Actuators Data sheet 2.5 mm 4.5 mm 2.5 mm – Floor heating – Fan coil units – Zone control SFA.. SUA21/1 STA.. SSA31.04 1) N4863 N4830 N4884 N4860 200 N 150 N 100 N 160 N Operating voltage Positioning signal Positioning time [s] Spring return function [s] AC 230 V 2-position 10 30–50 SFA21/18 – – – 2-position 210 – – – STA23 – 2-position/SPST 2) 10 – – SUA21/3 – – 3-position/SPDT 2) 43 – – – – SSA31.04 AC 24 V 2-position 10 30–50 SFA71/18 – – – 0…10 V 270 3) – – – STA63 – AC/DC 24 V 2-position/PDM 270 – – – STA73 – PN 16 1…110 °C DN Rp [Inch] k vs [m 3 /h] ∆p s [kPa] ∆p max [kPa] ∆p s [kPa] ∆p max [kPa] ∆p s [kPa] ∆p max [kPa] ∆p s [kPa] ∆p max [kPa] Data sheet N4842 VVI46.15 15 Rp ½ 2 300 300 300 300 200 200 200 200 VVI46.20 20 Rp ¾ 3.5 300 300 300 300 200 200 200 200 VVI46.25 25 Rp 1 5 300 300 250 250 200 200 200 200 VXI46.15 4) 15 Rp ½ 2 – 300 – 300 – 200 – 200 VXI46.20 4) 20 Rp ¾ 3.5 – 300 – 300 – 200 – 200 VXI46.25 4) 25 Rp 1 5 – 300 – 300 – 200 – 200 VXI46.25T 5) 25 Rp 1 5 – 200 – 200 – 200 – 200 Thermal actuators and connecting cables for combinable range, STx..3.. Color White Black Equipped with – Function module DC 0…10 V Auxiliary switch for STA Auxiliary switch for STP LED – Positioning signal 2-position (On/Off) DC 0…10 V DC 0…10 V 2-position (On/Off) 2-position (On/Off) 2-position (On/Off) 2-position (On/Off) [STA.., NC] [STA.., NC] – [STA.., NC] – [STA.., NC] [STA.., NC] [STP.., NO] – [STP.., NO] – [STP.., NO] [STP.., NO] [STP.., NO] Standard PVC cables 1 m ASA23U10 ASP23U10 2 m ASY23L20 ASY6AL20 ASY6PL20 ASY23L20LD 3 m ASY23L30B 5 m ASY23L50 ASY23L50B 10 m ASY23L100 15 m ASY23L150 Halogen-free cables 2 m ASY23L20HF ASY6AL20HF ASY6PL20HF 5 m ASY23L50HF 10 m ASY23L100HF Actuator STA73/00     STA23/00   STP73/00     STP23/00   STA73PR/00 6)    STP73PR/00 6)    STA73MP/00 7)     STA23MP/00 7)   STA73B/00  STA23B/00  1) Not suited for radiator valves 2) SPST = single-pole single-throw, SPDT = single-pole double-throw 3) In control mode (warm-up time) min. running time approx. 30 s/mm 4) 70% k vs in bypass‚ leakage rate in bypass 2...5% of k vs value 5) 100% k vs in bypass‚ leakage rate in bypass 0.05% of kvs value. For noiseless operation, the value of 100 kPa should not be exceeded. 6) Actuators ideal for parallel running. Pulse duration modulation (PDM) in connection with Siemens room controllers of the Desigo™ range and room thermostats. 7) Multipack with 50 actuators (OEM) NC: normally closed, NO: normally open Acvatix Valves and Actuators BİNA OTOMASYON ÜRÜNLERİ /SEÇİM TABLOLARI

RkJQdWJsaXNoZXIy MTczMDA=